<?xml version="1.0" encoding="utf-8" standalone="yes"?><rss version="2.0" xmlns:atom="http://www.w3.org/2005/Atom"><channel><title>NDS-4600-JD-05 on GpMidi.Net - Beard Stuff</title><link>https://www.gpmidi.net/tags/nds-4600-jd-05/</link><description>Recent content in NDS-4600-JD-05 on GpMidi.Net - Beard Stuff</description><generator>Hugo</generator><language>en-us</language><lastBuildDate>Thu, 12 Dec 2024 14:49:39 +0000</lastBuildDate><atom:link href="https://www.gpmidi.net/tags/nds-4600-jd-05/index.xml" rel="self" type="application/rss+xml"/><item><title>6Gbps vs 12Gbps based 60-Bay DAS Unit Performance</title><link>https://www.gpmidi.net/posts/2024/6gbps-vs-12gbps-based-60-bay-das-unit-performance/</link><pubDate>Thu, 12 Dec 2024 14:43:52 +0000</pubDate><guid>https://www.gpmidi.net/posts/2024/6gbps-vs-12gbps-based-60-bay-das-unit-performance/</guid><description>I use a bunch of 60-bay DAS units for my spinning rust at home. The performance difference between the units with 6Gbps SAS and 12Gbps SAS is definitely notable. Read more here!</description></item><item><title>NDS-4600 - All That Is Known</title><link>https://www.gpmidi.net/posts/2021/nds-4600-all-that-is-known/</link><pubDate>Tue, 20 Apr 2021 13:42:40 +0000</pubDate><guid>https://www.gpmidi.net/posts/2021/nds-4600-all-that-is-known/</guid><description>&lt;p&gt;&lt;a href="https://docs.google.com/document/d/1dyqGBxTc8DLuK0BaVmCf25lSXQxAQcj042XQkgSXNuc/edit?usp=sharing"&gt;This document which covers what we know of the NDS-4600&lt;/a&gt; has been written with help from &lt;a href="https://old.reddit.com/user/Offspring"&gt;/u/Offspring&lt;/a&gt;.&lt;/p&gt;</description></item><item><title>NDS-4600 Changing Zoning</title><link>https://www.gpmidi.net/posts/2021/nds-4600-changing-zoning/</link><pubDate>Tue, 23 Mar 2021 15:57:42 +0000</pubDate><guid>https://www.gpmidi.net/posts/2021/nds-4600-changing-zoning/</guid><description>&lt;h2&gt;Overview&lt;/h2&gt;&#10;&lt;p&gt;Thanks to a note and a good find by &lt;a href="https://old.reddit.com/user/DerUlmer"&gt;/u/DerUlmer&lt;/a&gt; I can now say there is a known way to change the zoning for the NDS-4600: &lt;/p&gt;&#10;&lt;p&gt;See the section for "Changing the zoning"&lt;/p&gt;&#10;&lt;p&gt;https://blog.carlesmateo.com/2019/06/07/dealing-with-performance-degradation-on-zfs-draid-rebuilds-when-migrating-from-a-single-processor-to-a-multiprocessor-platform/&lt;/p&gt;&#10;&lt;h2&gt;Steps&lt;/h2&gt;&#10;&lt;p&gt;Note: I've not tested this (yet). &lt;/p&gt;&#10;&lt;ol&gt;&#10;&lt;li&gt;&lt;span&gt;&lt;span&gt;&lt;span&gt;&lt;span&gt;&lt;span&gt;&lt;span&gt;Determine the SCSI device of the chassis&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&#10;&lt;ol&gt;&#10;&lt;li&gt;&lt;span&gt;&lt;span&gt;&lt;span&gt;&lt;span&gt;&lt;span&gt;&lt;span&gt;You can use `sg_map` or `lsblk`&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/li&gt;&#10;&lt;li&gt;&lt;span&gt;&lt;span&gt;&lt;span&gt;&lt;span&gt;&lt;span&gt;&lt;span&gt;sg_map example: &lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;br/&gt;&#10;&lt;span&gt;&lt;span&gt;&lt;span&gt;&lt;span&gt;&lt;span&gt;&lt;span&gt;[root@stor0 ~]# sg_map -i|grep NDS&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;br/&gt;&#10;&lt;span&gt;&lt;span&gt;&lt;span&gt;&lt;span&gt;&lt;span&gt;&lt;span&gt;/dev/sg35  NEWISYS   NDS-4600-JD       0509&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/li&gt;&#10;&lt;/ol&gt;&#10;&lt;/li&gt;&#10;&lt;li&gt;&lt;span&gt;&lt;span&gt;&lt;span&gt;&lt;span&gt;&lt;span&gt;&lt;span&gt;Set the zoning&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&#10;&lt;ol&gt;&#10;&lt;li&gt;&lt;span&gt;&lt;span&gt;&lt;span&gt;&lt;span&gt;&lt;span&gt;&lt;span&gt;For zone config 0:&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;br/&gt;&#10;&lt;span&gt;&lt;span&gt;&lt;span&gt;&lt;span&gt;&lt;span&gt;&lt;span&gt;sg_senddiag /dev/sg35  --pf --raw=04,00,00,01,50&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/li&gt;&#10;&lt;li&gt;&lt;span&gt;&lt;span&gt;&lt;span&gt;&lt;span&gt;&lt;span&gt;&lt;span&gt;For zone config 1:&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;br/&gt;&#10;&lt;span&gt;&lt;span&gt;&lt;span&gt;&lt;span&gt;&lt;span&gt;&lt;span&gt;sg_senddiag /dev/sg35  --pf --raw=04,00,00,01,51&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/li&gt;&#10;&lt;li&gt;&lt;span&gt;&lt;span&gt;&lt;span&gt;&lt;span&gt;&lt;span&gt;&lt;span&gt;For zone config 2:&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;br/&gt;&#10;&lt;span&gt;&lt;span&gt;&lt;span&gt;&lt;span&gt;&lt;span&gt;&lt;span&gt;sg_senddiag /dev/sg35  --pf --raw=04,00,00,01,52&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/li&gt;&#10;&lt;li&gt;&lt;span&gt;&lt;span&gt;&lt;span&gt;&lt;span&gt;&lt;span&gt;&lt;span&gt;For zone config 3:&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;br/&gt;&#10;&lt;span&gt;&lt;span&gt;&lt;span&gt;&lt;span&gt;&lt;span&gt;&lt;span&gt;sg_senddiag /dev/sg35  --pf --raw=04,00,00,01,53&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/li&gt;&#10;&lt;/ol&gt;&#10;&lt;/li&gt;&#10;&lt;li&gt;&lt;span&gt;&lt;span&gt;&lt;span&gt;&lt;span&gt;&lt;span&gt;&lt;span&gt;Wait 1 minute (aka `sleep 60`)&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/li&gt;&#10;&lt;li&gt;&lt;span&gt;&lt;span&gt;&lt;span&gt;&lt;span&gt;&lt;span&gt;&lt;span&gt;Reboot the controller&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;br/&gt;&#10;&lt;span&gt;&lt;span&gt;&lt;span&gt;&lt;span&gt;&lt;span&gt;&lt;span&gt;sg_senddiag /dev/sg35  --pf --raw=04,00,00,01,43&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/li&gt;&#10;&lt;li&gt;&lt;span&gt;&lt;span&gt;&lt;span&gt;&lt;span&gt;&lt;span&gt;&lt;span&gt;Run `rescan-scsi-bus.sh` or equivalent&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/li&gt;&#10;&lt;/ol&gt;&#10;&lt;h2&gt;&lt;span&gt;&lt;span&gt;&lt;span&gt;&lt;span&gt;&lt;span&gt;&lt;span&gt;Zoning &lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;Configurations&lt;/h2&gt;&#10;&lt;p&gt; &lt;/p&gt;</description></item><item><title>The One Problem With My Racks &amp; The NDS-4600-JD-05</title><link>https://www.gpmidi.net/posts/2021/the-one-problem-with-my-racks-the-nds-4600-jd-05/</link><pubDate>Wed, 06 Jan 2021 15:10:48 +0000</pubDate><guid>https://www.gpmidi.net/posts/2021/the-one-problem-with-my-racks-the-nds-4600-jd-05/</guid><description>&lt;p&gt;My zero-U PDUs get covered up as my rack isn't super super deep. &lt;/p&gt;</description></item><item><title>NDS-4600 - SATA Drive Failures In Linux</title><link>https://www.gpmidi.net/posts/2020/nds-4600-sata-drive-failures-in-linux/</link><pubDate>Tue, 01 Dec 2020 22:01:58 +0000</pubDate><guid>https://www.gpmidi.net/posts/2020/nds-4600-sata-drive-failures-in-linux/</guid><description>&lt;p&gt;One issue I've recently run into with a failed SATA drive in one of my NDS-4600 units is that Linux frequently tries to recover the drive by resetting the bus. This takes out a few other disks in the group with it. The resulting IO timeouts cause problems for my Ceph OSDs using those disks. &lt;/p&gt;&#10;&lt;p&gt;It should be noted that only some types of disk failures cause this. The host bus resets only are done by the Linux kernel in some cases (I think) and I suspect the cause of the other disks errors is said disk. &lt;/p&gt;</description></item><item><title>23TiB On CephFS &amp; Growing</title><link>https://www.gpmidi.net/posts/2020/23tib-on-cephfs-growing/</link><pubDate>Sun, 24 May 2020 17:37:49 +0000</pubDate><guid>https://www.gpmidi.net/posts/2020/23tib-on-cephfs-growing/</guid><description>&lt;h2&gt;&lt;a href="https://redd.it/gpuljd"&gt;Original post on Reddit&lt;/a&gt;&lt;/h2&gt;&#10;&lt;h2&gt; &lt;/h2&gt;&#10;&lt;h2&gt;Hardware&lt;/h2&gt;&#10;&lt;p&gt;Previously I &lt;a href="https://old.reddit.com/r/DataHoarder/comments/eyqay1/racked_two_used_60bay_das_units_nds4600jd05/"&gt;posted about the used 60-bay DAS units I recently acquired and racked&lt;/a&gt;. Since then I've &lt;a href="https://www.gpmidi.net/taxonomy/term/48"&gt;figured out the basics of using them&lt;/a&gt; and have them up and working. &lt;/p&gt;&#10;&lt;h2&gt;&lt;br/&gt;&#13;&#10;Ceph&lt;/h2&gt;&#10;&lt;p&gt;The current setup has one unit with 60 2TB-3TB drives attached to a single R710. The other unit has 22 2TB, 3TB, and 8TB disks. It's attached to one active R710. Although as the number of 8TB disks grows I'll be forced to attached the other two R710s to it. The reason for this is [Ceph](https://ceph.io/) OSDs need 1GB of RAM per OSD plus 1GB of RAM per TB of disk. The R710s each have 192GB of RAM in them. &lt;/p&gt;</description></item><item><title>Admin Access To NEWISYS NDS-4600-JD</title><link>https://www.gpmidi.net/posts/2020/admin-access-to-newisys-nds-4600-jd-103/</link><pubDate>Sat, 25 Apr 2020 22:50:55 +0000</pubDate><guid>https://www.gpmidi.net/posts/2020/admin-access-to-newisys-nds-4600-jd-103/</guid><description>&lt;ul&gt;&#10;&lt;li&gt;One IP per mgmt card&lt;/li&gt;&#10;&lt;li&gt;TCP/23&#13;&#10;&#9;&lt;ul&gt;&#10;&lt;li&gt;Basic telnet&lt;/li&gt;&#10;&lt;li&gt;No login&lt;/li&gt;&#10;&lt;li&gt;Can control various backplane options&#13;&#10;&#9;&#9;&lt;ul&gt;&#10;&lt;li&gt;Working on finding out how to control backplane mode&lt;/li&gt;&#10;&lt;/ul&gt;&#10;&lt;/li&gt;&#10;&lt;/ul&gt;&#10;&lt;/li&gt;&#10;&lt;li&gt;TCP/1138&#13;&#10;&#9;&lt;ul&gt;&#10;&lt;li&gt;Not TLS&#13;&#10;&#9;&#9;&lt;ul&gt;&#10;&lt;li&gt;openssl s_client causes it to restart&lt;/li&gt;&#10;&lt;/ul&gt;&#10;&lt;/li&gt;&#10;&lt;li&gt;Telnet??&lt;/li&gt;&#10;&lt;li&gt;Need to fuzz this&lt;/li&gt;&#10;&lt;/ul&gt;&#10;&lt;/li&gt;&#10;&lt;/ul&gt;</description></item><item><title>Admin Access To NEWISYS NDS-4600-JD</title><link>https://www.gpmidi.net/posts/2020/admin-access-to-newisys-nds-4600-jd/</link><pubDate>Sat, 18 Apr 2020 22:50:31 +0000</pubDate><guid>https://www.gpmidi.net/posts/2020/admin-access-to-newisys-nds-4600-jd/</guid><description>&lt;p&gt;Guess what has telnet enabled and TCP/1138. Telnet is obvious but I'm still working on TCP/1138. &lt;/p&gt;&#10;&lt;blockquote&gt;&#10;&lt;pre&gt;&#13;&#10;Expander Info&#13;&#10;--------------------------------&#13;&#10;Device ID : 8005&#13;&#10;Device Rev : C&#13;&#10;SAS Address : 500093d002856080&#13;&#10; Vendor : NEWISYS&#13;&#10; Product : NDS-4600-JD&#13;&#10;Product Rev : 0509&#13;&#10;Firmware Ver: 05.09.05&#13;&#10;PowerOn : Single Mode&#13;&#10; Slot : A&#13;&#10; Role : Secondary&#13;&#10; Address : 01&#13;&#10; Zoning Cfg : 00&#13;&#10;&lt;h2 id="init-string"&gt;Init String&lt;/h2&gt;&#10;&lt;pre&gt;&lt;code&gt;Device id : 8005&#13;&#10;&lt;/code&gt;&lt;/pre&gt;&#10;&lt;p&gt;Device Rev : C&#10;Flash tbl rv: 00000000&#10;EEPROM tbl rv: ffffffff&#10;Vendor :&#10;Product :&#10;Revision : 0509&#10;Vendor Spec : 05.09.05&#10;&lt;/pre&gt;&lt;/p&gt;</description></item><item><title>Two NDS-4600-JD-05</title><link>https://www.gpmidi.net/posts/2020/two-nds-4600-jd-05/</link><pubDate>Tue, 04 Feb 2020 13:41:44 +0000</pubDate><guid>https://www.gpmidi.net/posts/2020/two-nds-4600-jd-05/</guid><description>&lt;p&gt;These two NDS-4600-JD-05 units each have space for 60 3.5" drives with four 6 Gbps SAS ports on each of the two controllers. The plan is to connect two R610s (eventually R620s) to each of them with the DAS units partitioned so that each of the R610s/R620s has 30 disks (well, 15-disks on each of a pair of redundant 6 Gbps SAS lines). There will be a Ceph OSD per disk on each of the 30 disks. Half of the 30 disks will be 8TB and half will be either 3TB or 2TB disks. &lt;/p&gt;</description></item></channel></rss>